Rekisteröityneille asiakkaille 10% alennus kaikista normaalihintaisista tuotteista ja ilmaiset toimitukset yli 100€ tilauksille! (Muista rekisteröityä ennen tilauksen tekemistä!)

66W 350mA 60-190V LED virtalähde LCS135-70FX-01/220-240

Tilapäisesti loppunut

BAG Electronics

66W 350mA 60-190V LED virtalähde LCS135-70FX-01/220-240

Hinta
29,90 €
Saatavuus
Varastossa
Varastosaldo
2 kpl

Tuotekuvaus

• Non-dimmable 1-channel ECG for constant current operation of LED modules

• Non-SELV output voltage

• Very high efficiency of up to 93 % (100 % load)

• For use in luminaires of protection class I

• ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload

• Suitable for direct current operation and application in combination with central battery installations

• Certified as thermally protected device

• Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference

• Nominal service lifetime with a failure rate ≤ 10 %:

30,000 h at tc = tc,max

50,000 h at tc = tc,max - 10K

IP luokitus
IP20
Vakiovirta
350mA

Tarkka tuotekuvaus

LCS135-70FX-01/220-240 / 10116496
Output currents: 350mA
Output voltage /channel: 60 ... 190V
Total output power: 21 ... 66,5W
ECG efficiency: 93%


Mains voltage supply

Rated voltage range 220 ... 240 V

Max. permanent voltage range (continuous) 198 ... 264 V

Rated frequency 0 / 50 ... 60 Hz

Battery operation

Voltage range for continuous operation 198 ... 278 VDC

Lowest limiting value for temporary operation 176 VDC / 0.5 h

Mains overvoltage

Overvoltage protection 350 VAC / 2 h

Automatic switch-off of the LEDs at appr. 320 VAC

Protection against voltage peaks

Voltage peaks L - N 1 kV

Voltage peaks L/N -PE 2 kV

Starting time

Time to 100% luminous fl ux < 0.5 s

Total harmonic distortion (THD)

At 100% load to ECG-output < 10 %

Output data

Tolerance of output current +/- 10 %

Max. ripple of output current +/- 20 %

Max. wire length to LED module 2 m

Galvanic separation to mains input no

Protection functions output side

Overload operation yes; ECG switch-off, restart after mains interruption

Short-circuit operation yes; limitation of the output current

Open-circuit operation yes; ECG switch-off, restart after mains interruption

Lifetime

Operation at tc = tc,max 30,000 h; failure rate ≤ 10 %

Operation at tc = tc,max - 10 K 50,000 h; failure rate ≤ 10 %

Connection terminals

Type Terminal with release hole 1)

Wire cross section 0.5 mm² - 1.5 mm²

Wire stripping length 8 mm - 9 mm

Thermal protected device

Max. sureface temperature acc. to EN 61347-1/C5e + 110° C

Degree of protection

Degree of protection of ECG housing IP 20

Toimituskulut

PostNord MyPack Collect
7,50 €
Toimitus 1-3 työpäivän kuluessa lähtöpäivästä. Säilytysaika noutopisteessä 7 päivää.
PostNord MyPack Home Suomi
19,00 €
Kotiinkuljetus, toimitus 2-6 työpäivässä.
PostNord Suomi Parcel (Yrityksille)
12,00 €
Toimitus 1-3 työpäivässä. Ovelta ovelle palvelu yritysosoitteisiin.
Matkahuolto Lähellä-paketti
8,50 €
Toimitus pääsääntöisesti 2-5 työpäivää. 7 päivän säilytysaika pakettiautomaatissa ja noutopisteissä.
Posti Postipaketti
9,00 €
Toimitus 2-5 työpäivässä.
DB Schenker Noutopistepaketti
8,50 €
Toimitus 2-5 työpäivässä.
Nouto varastolta
0,00 €
Nouto varastoltamme Rajakivenkatu 8, 20740 Turku. HUOM! Nouto varastolta vain arkisin klo 9-15. Varasto suljettuna viikonloppuisin ja pyhäpäivinä. Tuotteet ovat valmiina noudettavaksi viimeistään 3 tunnin kuluttua tilauksesta.

Lahjakortti