Rekisteröityneille asiakkaille 10% alennus kaikista normaalihintaisista tuotteista ja ilmaiset toimitukset yli 100€ tilauksille! (Muista rekisteröityä ennen tilauksen tekemistä!)

12.5W ~ 95W 2x250..900mA DALI himmennettävä LED virtalähde

BAG Electronics

12.5W ~ 95W 2x250..900mA DALI himmennettävä LED virtalähde

Hinta
63,23
Saatavuus
Tilapäisesti loppunut
Varastosaldo
0 kpl

Tuotekuvaus

BAG ICD290-100LS-01/220-240/DALI

  • Dimmable 2 channel ECG for constant current operation of LED modules
  • Programmable functions* for modification according to specific applications
    • Individual output current in range 250-900 mA per channel-Dimming method: selection between Amplitude, PWM (500 Hz) and Mixed Mode
    • Compensation of LED degradation during operating time
    • Selection between 1 and 2 DALI addresses
    • Temperature-dependent control of output currents
    • Adjustment of output currents by means of resistors
  • Detect & React interface: analogue interface for connecting sensors e.g. for temperature or light detection
  • SELV equiv. output voltage ≤ 60 VDC
  • Very high efficiency of up to 90 % (100 % load)
  • Soft start and low output current ripple
  • For use in luminaires of protection class I
  • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit, underload or overload
  • Suitable for direct current operation and application in combination with central battery installations
  • Push-DIM function of DALI interface: switching and dimming via push-button
  • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference
  • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc = tc,max
    * Programming via software ZITARES 360
IP luokitus
IP20
Vakiovirta
250mA
900mA

Tarkka tuotekuvaus

Output voltage /channel: 25-53V
Output currents: 2 x 250 ... 900mA
Total output power: 12.5 ... 95 W
ECG efficiency: 91%


General technical data

Mains voltage supply

Rated voltage range 220 ... 240 V

Max. permanent voltage range (continuous) 198 ... 264 V

Rated frequency 0 / 50 ... 60 Hz

Battery operation

Voltage range for continuous operation 198 ... 278 VDC

Lowest limiting value for temporary operation 176 VDC / 0.5 h

Mains overvoltage

Overvoltage protection 350 VAC / 2 h

Automatic switch-off of the LEDs at appr. 350 VAC

Protection against voltage peaks

Voltage peaks L - N 1 kV

Voltage peaks L/N -PE 2 kV

Starting time

Time to 100% luminous fl ux < 0.5 s

Total harmonic distortion (THD)

At 100% load to ECG-output < 10 %

Output data

Tolerance of output current +/- 5 %

Max. ripple of output current +/- 10 %

Max. wire length to LED module 2 m

Galvanic separation to mains input yes, test voltage 3.75 kV

Protection functions output side

Overload operation yes; limitation of output voltage and reduction of output current

Underload / Short-circuit operation yes; output channel swich-off in case of permanent operation,

restart after mains interruption

Open-circuit operation yes; output voltage max. 60 VDC (SELV equiv.)

Hot plug-in allowed; protection of LED module has to be ensured

Dimming operation and interface

Overvoltage protection of interface 264 VAC

Galvanic separation to output side yes, test voltage 3.75 kV

Stand-by power losses ≤ 0.5 W

Dimming range for luminous fl ux 1 ... 100 %

Dimming technology 500 Hz (PWM) or Amplitude or Mixed Mode 2)

Max. number of ECG for Push-Dim control 25

Detect & React interface

Overvoltage protection of interface 60 VDC

Range of contral voltage 0 ... 10 VDC

Range of resistance detection (resolution) 0 ... 10 kΩ (100 Ω)

Max. control current 4 mA

Connection terminals

Type 90°-terminal with key 1)

Wire cross section 0.5 mm² - 1.5 mm²

Wire stripping length 7.5 mm - 8.5 mm

Thermal protected device

Max. sureface temperature acc. to EN 61347-1/C5e + 110° C

Degree of protection

Degree of protection of ECG housing IP 20

1) Terminals and ECG construction are designed for an automatic wiring with robots

2) See page 8 ‟dimming methods“ for futher interformation


Temperatures

Ambient (ta) – 25 °C ... +50 °C

Case (tc) max. + 75 °C

Lifetime

Operation at tc = tc,max 50,000 h; failure rate ≤ 10 %
Operation at tc = tc,max - 10 K 100,000 h; failure rate ≤ 10 %

Toimituskulut

PostNord MyPack Collect
7,50 €
Toimitus 1-3 työpäivän kuluessa lähtöpäivästä. Säilytysaika noutopisteessä 7 päivää.
PostNord MyPack Home Suomi
19,00 €
Kotiinkuljetus, toimitus 2-6 työpäivässä.
PostNord Suomi Parcel (Yrityksille)
12,00 €
Toimitus 1-3 työpäivässä. Ovelta ovelle palvelu yritysosoitteisiin.
Matkahuolto Lähellä-paketti
8,50 €
Toimitus pääsääntöisesti 2-5 työpäivää. 7 päivän säilytysaika pakettiautomaatissa ja noutopisteissä.
Posti Postipaketti
9,00 €
Toimitus 2-5 työpäivässä.
DB Schenker Noutopistepaketti
8,50 €
Toimitus 2-5 työpäivässä.
Nouto varastolta
0,00 €
Nouto varastoltamme Rajakivenkatu 8, 20740 Turku. HUOM! Nouto varastolta vain arkisin klo 9-15. Varasto suljettuna viikonloppuisin ja pyhäpäivinä. Tuotteet ovat valmiina noudettavaksi viimeistään 3 tunnin kuluttua tilauksesta.

 

 

 

 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 

Lahjakortti